No.8

Introduction
Data Policy
Data
Documentation
Contact Information



Zugspitze / Schneefernerhaus

-CO-

back
Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : Local time 1


Sampling
Sampling height :
Description : continuous
Sampling and analysis frequency : Continuous
Sampling environment :
Description for sampling analysis : Height of the line is 20 meters above the ground and 2.5m over the top of the measurement station.


Instrument and Analysis
Measurement method :
Current status and history of instrument : Gas filter correlation
Description of instrument : Thermo Environmental Instruments Inc.


Modified HP 6890 Chem. station, # US00030144


Calibration
Current scale employed in the measurement : WMO mole fraction scale
Measurement calibration : Calibration gas: CO in naturals gas. Calibrations are carried out every 25 hours using tanks, which have been calibrated in a laboratory of the NOAA/CMDL
Scale and calibration(treasability) : All data are based on WMO mole fraction scale. (NOAA/CMDL)


Data Processing
Measurement unit : ppb
Data processing : All values are quality controlled.
Processing for averaging : Processing for Hourly Data:
The data acquisition system provides one minute mean raw data. Zero/calibration factors and data protocols are used to convert raw data into calibrated data. Invalid data caused by local impact, malfunction or other effects are detected by comparison/ correlation with other trace substances and meteorological data and with information from the station logbook and then are rejected. 30 min mean values are generated by calculating the arithmetic mean of the remaining data with number of data more than 15. For reporting to GAW hourly mean values are calculated from these half hourly data.
Processing for Daily Data:
Daily: Take the arithmetic mean of selected half hourly data with the number of data more than 31.
Processing for Monthly Data:
Monthly: Take the arithmetic mean of selected half hourly data with the number of data more than 960.
Data flag : Hourly
...- 2005: 1 = valid value, 6 = calibration, 9 = error code
2006 -...: 0 = valid value, 3 = invalid data, 6 = calibration
Data remarks :


Other Information
Scientific aim : To provide reliable data for research to reveal long term trends of air pollution, long distance transport and climate change in Central Europe.
Reference : "Qualitatssicherungs-Handbuch des UBA-Messnetzes", UBA Texte 28/04, (Handbook for quality assurance for the measurement network for the Federal Environmental Agency, Germany), Dr.Klaus Nienerowski, Umweltbundesamt, Berlin, Juni 2004

http://www.umweltbundesamt.de/luft/luftmessnetze/ubamessnetz.htm


submitted by Federal Environmental Agency Germany



The WDCGG is operated by the Japan Meteorological Agency
in collaboration with the World Meteorological Organization