No.8

Introduction
Data Policy
Data
Documentation
Contact Information



Amsterdam Island

-CO-

back
Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : UTC


Sampling
Sampling height : 70
Description : continuous
Sampling and analysis frequency : GC-RGD2 Continuous Measurements. Sequential measurement (1 measurement every 6 min, 1 standard every 6 min).
Sampling environment : Amsterdam Island
Sampling site = Pointe Bénédicte

The station is situated on a cliff, 70 m.a.s.l. No obstacles in surroundings. At distance of 2 km from base Martin-de-Viviès, the only pollution source on the Island.
Description for sampling analysis : Location of air intake : At top of tower. Height 15 m. Distance from station 20 m.
Description sampling line : Dekabon. Diameter: 10 mm. Length: 41 m.
Chemical trap: Magnesium perchlorate


Instrument and Analysis
Measurement method : Gas Chromatography (RGD)
Current status and history of instrument : Period in use = 1996-2000 & 2004-2009
Description of instrument : Manufacturer of GC system: Trace Analytical
Model and S/N: RGA3, RGA3-101590-007
Detector type(s) and manufacturer: GC-HgO reduction/ UV absorption
Temperature: 268° C
Carrier gas: N2 GC50. Manufacturer: Getters
Sample loop volume: 1 mL




Calibration
Current scale employed in the measurement : Range between (35 and 65 ppb), check with average annual oscillation.
Measurement calibration : Sequence of analyses (A: ambient; W: working standard; L: laboratory standard) : A (2.5 minutes), W (2.5 minutes)

Scale and calibration(treasability) : Working standard in operation (S/N, since when?): 30.09.2007, S/N: 597701

Laboratory standard: Type of cylinder = Volume: 0.05 m3. Fabrication date: 10.12.2004. Manufacturer: NOAA. Calibration scale 104.8 ppb (primary CO)

Working standard: 8.3.3 Type of cylinder = Size: 20 L. Pressure: 150 bar. Fabrication date: 17.05.2006. Manufacturer: Messer, France. Calibration scale 102 ppb


Data Processing
Measurement unit : ppb
Data processing : DATA ACQUISITION AND PROCESSING
Manufacturer: Borwin, Type1.21
Which instrumental (system) parameters are recorded? Ambient temperature, pressure, sample in flow, peak area, peak height.
Processing for averaging : Processing for Hourly Data:
Hourly average

Data flag :
Data remarks :


Other Information
Scientific aim :
Reference :


submitted by Laboratoire des Sciences du Climat et de l'Environnement



The WDCGG is operated by the Japan Meteorological Agency
in collaboration with the World Meteorological Organization