Burgas
-NO2-
Observation |
Category |
: |
Air sampling observation |
Situation |
: |
ongoing |
Time zone |
: |
UTC |
Sampling |
Sampling height |
: |
|
Description |
: |
continuous |
Sampling and analysis frequency |
: |
Several times a day |
Sampling environment |
: |
|
Description for sampling analysis |
: |
Sampling duration is 1/2 hour. Four samples per day are made, at 6, 9, 12 and 15 UTC. Starting with August 2002 six measurements per day (at 0,6,9,12,15 and 18 UTC) form the diurnal mean values. Single beam spectrometer with continuous spectrum and manual adjustment of the beam. Spectral interval is 350-850 nm. Measurement for NO2 is oerformed at 520 nm. |
Instrument and Analysis |
Measurement method |
: |
|
Current status and history of instrument |
: |
Spectrophotometer |
Description of instrument |
: |
Karl Zeiss, Jena SPECOL 11 |
Calibration |
Current scale employed in the measurement |
: |
|
Measurement calibration |
: |
The method is photometric. Standard solutions are prepared at the stations every 3 days. Acalibration curve is plotted and used in measurement procedure. The sensitivity of the method is 0.1 microgram per 3 ml measured solution. A solution of Griss' reagent is used during the measurements. The relative error of the method is 15%. the method is registered under Bulgarian State Standard (BSS)-BSS 17.2.4.22-83 |
Scale and calibration(treasability) |
: |
|
Data Processing |
Measurement unit |
: |
mg/m3-25C |
Data processing |
: |
|
Processing for averaging |
: |
Processing for Daily Data: Arithmetic mean from the four measurements.
Processing for Monthly Data: Arithmetic mean of the daily data. |
Data flag |
: |
|
Data remarks |
: |
|
Other Information |
Scientific aim |
: |
|
Reference |
: |
|
|
submitted by National Institute of Meteorology and Hydrology |
|
|