Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : Local time 1


Sampling
Sampling height :
Description : continuous
Sampling and analysis frequency : Continuously one value every 2.5minutes
Sampling environment :
Description for sampling analysis : Chemiluminescence detection of NO, Conversion of NO2 to NO with specific photolysis converter. Height of the line is 20 meters above the ground and 2.5m over the top of the measurement station.


Measurement of NO with chemiluminescence (reaction with O3) detection, (LDL " 50 ppt).


Instrument and Analysis
Measurement method : Chemiluminescence
Current status and history of instrument : Chemiluminescence
Description of instrument : ECO Physics AG


Cranox, # 77320


Calibration
Current scale employed in the measurement : EUROTRAC/TOR project
Measurement calibration : Calibration gas: dynamic dilution, NO in air. Calibrations are carried out every 48 to 72 hours. The precision gas phase dilution device is calibrated according to NIST standards.
Scale and calibration(treasability) : Certified NO concentrations in cylinders are used for calibration, validated by international intercomparisons (e.g. EUROTRAC/TOR project)


Data Processing
Measurement unit : µg/m³ - 20 °C
Data processing : All values are quality controlled.
Processing for averaging : Processing for Hourly Data:
The data acquisition system provides one raw data every 2.5 minutes. Zero/calibration factors and data protocols are used to convert raw data into calibrated data. Invalid data caused by local impact, malfunction or other effects are detected by comparison/ correlation with other trace substances and meteorological data and with information from the station logbook and then are rejected. 30 min mean values are generated by calculating the arithmetic mean of more than 2/3 of the remaining data. For reporting to gaw hourly mean values are calculated from these half hourly data.
Processing for Daily Data:
Daily: Take the arithmetic mean of selected half hourly data with the number of data more than 31.
Processing for Monthly Data:
Monthly: Take the arithmetic mean of selected half hourly data with the number of data more than 960.
Data flag : Hourly
...- 2005: 1 = valid value, 6 = calibration, 9 = error code
2006 -...: 0 = valid value, 3 = invalid data, 6 = calibration
Data remarks :


Other Information
Scientific aim : To provide reliable data for research to reveal long term trends of air pollution, long distance transport and climate change in Central Europe.
Reference : "Qualitatssicherungs-Handbuch des UBA-Messnetzes", UBA Texte 28/04, (Handbook for quality assurance for the measurement network for the Federal Environmental Agency, Germany), Dr.Klaus Nienerowski, Umweltbundesamt, Berlin, Juni 2004

http://www.umweltbundesamt.de/luft/luftmessnetze/ubamessnetz.htm


submitted by Federal Environmental Agency Germany