| ![](../../../figure/gaw_stations.gif)
Neumayer
-O3-
Observation |
Category |
: |
Air sampling observation |
Situation |
: |
ongoing |
Time zone |
: |
UTC |
Sampling |
Sampling height |
: |
8 |
Description |
: |
continuous |
Sampling and analysis frequency |
: |
Continuous; one minute averages are validated and archived. |
Sampling environment |
: |
The dominant source of surface ozone for Antarctica is mainly transport of upper troposheric or stratospheric air. Local photochemistry acts as a sink due to very low NOx mixing ratios (around 2-5 pptv). |
Description for sampling analysis |
: |
Ambient air is continuously sampled through a teflon tube by a vacuum pump (flow rate 1.6 L/min) |
Instrument and Analysis |
Measurement method |
: |
Light absorption analysis (UV) |
Current status and history of instrument |
: |
EEC (1982-1994) , UV Photometer(1995-) Environment s.a. type O3-41M |
Description of instrument |
: |
Environment s.a.
Environment s.a. ozone analyzer type O3-41M |
Calibration |
Current scale employed in the measurement |
: |
Observer's standard scale |
Measurement calibration |
: |
internal O3 calibration source, comparison with second O3 analyzer and ECC-sondes |
Scale and calibration(treasability) |
: |
|
Data Processing |
Measurement unit |
: |
ppb |
Data processing |
: |
the original data resolution is 1 minute since the year 2000 and 3 minutes before 2000. Data taken during zeroing periods, calibration or instrument malfunction were removed. |
Processing for averaging |
: |
Processing for Hourly Data: 1 hour means were calculated from the validated one-minute averages.
|
Data flag |
: |
-9999.99 |
Data remarks |
: |
|
Other Information |
Scientific aim |
: |
Scientific aim of observation is to investigate tropospheric ozone minima and to provide long-term surface ozone data in the pristine troposphere |
Reference |
: |
|
|
submitted by Alfred Wegener Institute and Deutscher Wetterdienst |
|
|