Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : UTC


Sampling
Sampling height : 6
Description : continuous
Sampling and analysis frequency : Continuous
Sampling environment : Coastal
Influenced by local pollution, fires, and transport
Description for sampling analysis : Teflon inlet and inlet line with PTFE filter membrane
1-3 lpm sample flow rate


Instrument and Analysis
Measurement method : Light absorption analysis (UV)
Current status and history of instrument : 2002.04- :TEI 49C
Description of instrument : 1.0 ppb precision
+/- 1.0% full scale linearity


Calibration
Current scale employed in the measurement : the NIST standard
Measurement calibration : 0-200 ppb calibration scale
NIST standard for ozone production
Scale and calibration(treasability) : NIST standard
Calibrated February 2012


Data Processing
Measurement unit : ppb
Data processing : All data in scrutinized to ensure that data is removed that has been influenced by an external factor. All other data is used for the most complete data set
Processing for averaging : Processing for Hourly Data:
all data averaged
Processing for Daily Data:
all data averaged
Processing for Monthly Data:
all data averaged
Data flag :
Data remarks :


Other Information
Scientific aim : Measurement of background air quality over the eastern Pacific and detection of transpacific pollution.

Local Pollution studies
Effects of Wildfires on surface level ozone
Reference : http://www.esrl.noaa.gov/gmd/ozwv/surfoz/index.html


submitted by Earth System Research Laboratory, NOAA



The WDCGG is operated by the Japan Meteorological Agency