No.8

Introduction
Data Policy
Data
Documentation
Contact Information



Lauder

-O3-

back
Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : UTC


Sampling
Sampling height : 6
Description : continuous
Sampling and analysis frequency : Continuous
Sampling environment : 670 m elevation
Local pollution
Description for sampling analysis : continuous sampling through inlet and teflon inlet line with PTFE filter membrane
1-3 lpm sample flow rate


Instrument and Analysis
Measurement method : Light absorption analysis (UV)
Current status and history of instrument : UV Photometer
2003.01- :TEI 49-c
Description of instrument : TEI 49-c
1.0 ppb precision
+/- 1.% of full scale linearity


Calibration
Current scale employed in the measurement : the NIST standard
Measurement calibration : 0-200 ppb calibration scale
sample gas produced from NIST calibrated TEI standard
Scale and calibration(treasability) : Calibration from NIST Traceable standart TEI instrument: Calibrated February 2012


Data Processing
Measurement unit : ppb
Data processing : Instrument outputs in two files
1 hour records with instrument details
5 minute data averages

These files are processed to remove any data that has been marked as influenced by outside sources (ie. power outages, zero span checks, etc)
Data is collected and processed weekly
Processing for averaging : Processing for Hourly Data:
Average all data
Processing for Daily Data:
Average all data
Processing for Monthly Data:
average all data
Data flag :
Data remarks :


Other Information
Scientific aim : Measurement of background air quality over the eastern Pacific and detection of transpacific pollution.
NOx and VOC influences
Reference : http://www.esrl.noaa.gov/gmd/ozwv/surfoz/index.html


submitted by Earth System Research Laboratory, NOAA



The WDCGG is operated by the Japan Meteorological Agency
in collaboration with the World Meteorological Organization