| ![](../../../figure/gaw_stations.gif)
Puszcza Borecka/Diabla Gora
-O3-
Observation |
Category |
: |
Air sampling observation |
Situation |
: |
ongoing |
Time zone |
: |
|
Sampling |
Sampling height |
: |
|
Description |
: |
continuous |
Sampling and analysis frequency |
: |
Continous measurement, 30-min avarages stored by datalogger |
Sampling environment |
: |
|
Description for sampling analysis |
: |
UV-photometry, ML9810B |
Instrument and Analysis |
Measurement method |
: |
|
Current status and history of instrument |
: |
UV-photometry |
Description of instrument |
: |
Monitor Europe Ltd. PP-BN-30 |
Calibration |
Current scale employed in the measurement |
: |
0-500 ppb |
Measurement calibration |
: |
Every year with Standard Reference Photometr (SRPO nr 017) in Prague, Czech Republic |
Scale and calibration(treasability) |
: |
0-500 ppb |
Data Processing |
Measurement unit |
: |
ug/m3 |
Data processing |
: |
Stored 30-min data, calculated 1-hour data, daily, monthly, yearly averages
|
Processing for averaging |
: |
Processing for Hourly Data: Calculated based on 30-min results stored by data logger Processing for Daily Data: Calculated based on hourly data Processing for Monthly Data: Calculated based on daily data |
Data flag |
: |
999 missing measurement, unspecified reason 980 missing due to calibration 699 mechanical problem, unspecified reason 649 power failure 000 valid data |
Data remarks |
: |
|
Other Information |
Scientific aim |
: |
|
Reference |
: |
|
|
submitted by Institute of Environmental Protection |
|
|