No.8

Introduction
Data Policy
Data
Documentation
Contact Information



Arrival Heights

-O3-

back
Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : UTC


Sampling
Sampling height : 6
Description : continuous
Sampling and analysis frequency : Continuous
Sampling environment : 50m elevation
coastal influence
Antarctic analysis
Description for sampling analysis : Continuous sampling through 6m inlet and teflon inlet line with PTFE filter membrane
1-3 lpm sample flow rate


Instrument and Analysis
Measurement method : Light absorption analysis (UV)
Current status and history of instrument : 1996.12 - 2002.12 : DASIBI
2003.01 - : TEI
Description of instrument : TEI-49c
1.0 ppb precision
+/- 1.0% of full scale linearity


Calibration
Current scale employed in the measurement : the NIST standard
Measurement calibration : 0-200 ppb calibration scale
Sample gas produced from NIST-calibrated standard TEI instrument
Scale and calibration(treasability) : Calibration direct from NIST Traceable standard TEI instrument
Calibration standard from February 2012


Data Processing
Measurement unit : ppb
Data processing : instrument outputs in two files
1 hour records with instrument details
5 minute data averages
These files are then processed to remove any data that has been affected by outside influences (ie. power outage, zero span checks etc)
Data is collected and processed weekly
Processing for averaging : Processing for Hourly Data:
Average of all data
Processing for Daily Data:
Average of all data
Processing for Monthly Data:
Average of all data
Data flag :
Data remarks :


Other Information
Scientific aim : Measurement of background surface ozone.
NOx influence on surface level ozone.
Reference : http://www.esrl.noaa.gov/gmd/ozwv/surfoz/index.html


submitted by Earth System Research Laboratory, NOAA



The WDCGG is operated by the Japan Meteorological Agency
in collaboration with the World Meteorological Organization