No.8

Introduction
Data Policy
Data
Documentation
Contact Information



Pilar Observatorio

-O3-

back
Station Contact Person(s) Observation Data and Quick Plot

Observation
Category : Air sampling observation
Situation : ongoing
Time zone : UTC


Sampling
Sampling height : 3
Description : continuous
Sampling and analysis frequency : Continuous, measuring interval is 10 seconds (7 seconds flushing and 3 seconds integrating time).
Sampling environment : The Pilar Observatory is located at the centre of the Country (31.4°S, 63.53°W) at an altitude of 338 meters a.s.l. The distance from the Capital of Cordoba is approximately 60 Km.
The prevailing winds blow from the North-Northwestern sector (N-NW). The station is surrounded by a pasture land or field, but there is a cold-storage plant 2,5 kilometers to the North.
The average annual rainfall and relative humidity are 786 mm and 69%, respectively.
Description for sampling analysis : Sampling and Analyses Intake height: 3 m above ground on top of the station building, 1 m above the roof.
Inlet/Manifold: from there connections ozone instruments by t inch PFA tubing, length approx. 6 m to instrument.
Total flow rate 1.6 liter per minute
Teflon inlet filter before analyzer, exchanged monthly.
Residence time in the sampling line: approx. 2 s




Instrument and Analysis
Measurement method : Light absorption analysis (UV)
Current status and history of instrument : Instrument model TEI 49 \#49981-285
Product name: Model 49
Manufacturer: Thermo Environmental Instruments Inc
Since May. 1995 - to Aug. 1998 continued and Nov. 1998.
Since Jul. 1999 - to Oct 1999 continued.
Since Sep. 2004 - to Jan 2006 continued.
Since Mar. 2006 - to May 2006 continued.
Since Aug. 2006 - to Dec 2007 continued.
Since Oct. 2008 - to Dec 2008 continued and Feb. 2008.
Since Apr. 2009 - to Mar. 2010 continued.
Since Jun. 2010 Out of service throughout the year.
Instrument model TEI 49 \#54577-300
Product name: Model 49
Manufacturer: Thermo Environmental Instruments Inc
Period in use: from 2011 - at present
2011 It continues to be out of service.

Description of instrument : TEI 49 characteristics:
Internal ozone generator
Range: 0-100 ppb
Precision: 0.002 ppm
Linearity: ± 0.001 ppm
Noise: ± 0.001 ppm
Minimum detectable: Limit 0.002 ppm
Response Time: (0 to 95%) 20 seconds
Lag time: 10 seconds
Flow Rate: 1 – 3 liters per minutes
Analog output: 0-10 V


Calibration
Current scale employed in the measurement : Travelling standard, traceable to NIST
Measurement calibration : Intercomparison at the Regional Calibration Centre (RIII WMO) for Surface Ozone (RCC-BsAs) by WCC-Empa in 2006 and 2010.
Scale and calibration(treasability) : The data refer to the WCC O3 standard.
Absolute scale, ppb.


Data Processing
Measurement unit : ppb
Data processing : You should considerate that the wind blows from the North, the data since they are have been probably polluted by the cold-storage plant, since mid-2004.
Processing for averaging : Processing for Hourly Data:
The hourly mean value is calculated as the arithmetic mean value of the samples taken every 15 minutes.
Processing for Daily Data:
The daily value is calculated as the arithmetic mean value of the 24 hourly values taken during the day.
Processing for Monthly Data:
The monthly values are calculated as the arithmetic mean value of the days for that month.
Data flag : Flag 0– Valid data.
Flag 1- Invalid or suspect data
Data remarks :


Other Information
Scientific aim :
Reference :


submitted by National Weather Service



The WDCGG is operated by the Japan Meteorological Agency
in collaboration with the World Meteorological Organization